PREFACE
Protecto 401 lined ductile iron pipe and fittings
provide the maximum protection and the strength necessary to do the job in tough sewer
pipe applications. Protecto 401 has successfully been used in hundreds of sanitary sewer
applications and has been proven with both laboratory testing and years of actual sewer
service on all sizes of ductile iron pipe and fittings. (The development of Protecto 401
was begun in 1979. The first ductile iron sewer pipe was lined and placed in service in
1981. Since then hundreds of miles of ductile iron sewer pipe have been lined with
Protecto 401 with no lining failure.)
Because Protecto 401 Ceramic Epoxy Lining was
designed and is used as protection for ductile iron sanitary sewer pipe, it provides the
reliability of cement mortar lining with the excellent corrosion protection of novalac
epoxy. This concentration of effort has resulted in performance unparalleled by other
linings.
Protecto 401 has been tested extensively. This
website contains results of these tests and other data associated with lining for ductile iron sewer pipe.
Protecto 401 is applied to the interior of ductile
pipe and fittings utilizing specialized application equipment and a stringent
specification. The lining is designed to be applied at a nominal 40 mils thickness. A
pinhole detection test and a thickness test is performed to insure a sound, chemically
resistant protective lining for ductile iron pipe and fittings.
Protecto 401 is intended for use in domestic sanitary
sewage lines. Chemical injection for odor control may damage pipe, gaskets, and/or
protective linings and should be undertaken with extreme caution. Requests for industrial
sewer applications of Protecto 401 lined ductile pipe and fittings should be made to a
pipe marketing representative for individual recommendations. |